NVLAP Accredited Humidity Calibration - 10% to 95% (+/- 0.7%) Relative Humidity. Temperature range covered is 0°C to 70°C (+/- 0.06°C ).
Troemner
offers standard and custom calibration services for a wide
variety of humidity measuring devices including chart recorders/data
loggers, sensors, hygrothermographs, and hygrometers.
Humidity Calibration Services QuickLINKS:
> Facility
> Equipment
> Processes
> Humidity Calibration Services
> Humidity Calibration Service Request for Quote/Order Form
> Calibration Devices - Alphabetical List
> Calibration Devices Listed by Service
Facility
The Humidity
Calibration Laboratory is ISO/IEC
17025 compliant and accredited by NVLAP.
Environmental conditions in the Laboratory are strictly monitored
and controlled.
Equipment
Troemner’s
Humidity Calibration Laboratory utilizes the "two-pressure"
and "two-temperature" humidity generation process
developed and proven by NIST.
This design produces high precision humidity determinations
ideal for instrument calibration and evaluation. Laboratory
capabilities are 10% to 95% (+/- 0.7%) Relative Humidity.
Temperature range covered is 0°C to 70°C (+/- 0.06°C
).
Processes
Troemner
offers standard and custom humidity calibration procedures.
Troemner’s NVLAP Humidity Calibration Certificate is
a detailed, multi-page document designed to meet all regulatory
and audit requirements including all ISO (including ISO/IEC
17025), FDA, GMP, GLP, DOD, NCCLS, CLIA, ANSI/NCSL Z540-1,
and nuclear requirements. The NIST-administered National Voluntary
Laboratory Accreditation Program (NVLAP
Lab Code 105013-0) approves all procedures for this detailed
humidity certificate.
NVLAP
Calibration Certificate for Humidity (view
sample of certificate) – we provide a detailed,
multi-page humidity calibration certificate designed to meet
all regulatory and audit requirements including all ISO (including
ISO/IEC 17025), FDA, GMP, GLP, DOD, NCCLS, CLIA, ANSI/NCSL
Z540-1, and nuclear requirements. Technical data includes
"As Found" and "As Left" measurements
of applied and indicated humidity, standard temperature, temperature
of device under test, uncertainty of measurement process and
tolerance of device.
Humidity
Calibration Services Include:
- Calibration capabilities: 10% to 95% (+/- 0.7%) Relative Humidity
@ 0°C to 70°C (+/- 0.06°C)
- Types of instruments serviced include: Chart recorders/Data
loggers, Hygrothermographs, Sensors, and Hygrometers
- ISO/IEC 17025 compliant laboratory
- NVLAP accredited calibrations
- Fast turnaround time
Troemner offers
standard and custom calibration services. Below is a description
of the three standard humidity calibration services available
from Troemner:

|


Hummingbird Help Calibration Reminders: Troemner routinely sends out calibration reminders to assure your devices are monitored properly |
TROEMNER'S NATURAL FACTS

Water vapor will only condense onto another surface when that surface is cooler than the temperature of the water vapor, or when the water vapor equilibrium in air has been exceeded.
 |
|