Temperature Calibration

Temperature Calibration


At Troemner we address every variable of our measurement process to ensure consistency of calibration, which leads to accurate results in your processes, products and services. Fill out the form below with your Temperature Device and General Contact information to receive a quote within 24 hours.

Calibration Labs Image Gallery

Temperature Calibration Order Forms


An online order form is available at the bottom of the page. Below is a PDF of the Temperature Calibration Order Forms for reference.

Temperature Calibration Order Form

Calibration Certificates

Troemner offers certificates of calibration to meet all of your requirements. Click below to view our sample certificate.
NVLAP Accredited Temperature Certificate of Calibration

Accreditation

ISO/IEC 10725, NVLAP Accredited. NVLAP Laboratory Code 105013-0. Click here for Troemner's NVLAP Accredited Certificate

Laboratory Scope

From -196 °C to 660 °C for Comparison Calibrations and Fixed-Point Calibrations from the triple point of Argon to the Aluminum freezing point (-186.3443 °C to 660.323 °C). Liquid-in-glass calibrations from -35 °C to 250 °C. Click here for Troemner's NVLAP Scope of Accreditation

Service Levels

  • SPRT by Fixed-Point.
  • SPRT by Comparison to SPRT.
  • PRT by Comparison to SPRT.
  • Systems by Comparison to SPRT
  • Liquid in Glass by Comparison to SPRT

Devices Serviced

Include SPRT’s, RTD’s, PRT’s, thermistors, digital readouts, systems, liquid-in-glass thermometers, and thermocouples. Click for a list of Calibration Devices by Service.

Fast Turnaround Time

2 weeks. (Exception SPRT’s by fixed point 6-8 weeks)

Laboratory Personnel

Metrology staff and technicians are trained by the National Institute of Standards & Technology.

Laboratory Processes

Receive device at Troemner’s facility, visually inspect device, contact customer to review service levels requested, collect as-found calibration measurement data, adjust or repair device if required, collect as-left calibration measurement data, calibration certificate is reviewed by an approved signatory, device is packaged and returned to customer. Probe Calibrations undergo a stability and anealing process prior to calibration.

Need a Repair?

Troemner makes every effort to repair your device. If for any reason you need a repair that cannot be done in house we will facilitate a manufacturer repair on your behalf.

Green Packing Guidelines

Troemner's management systems are dedicated to efficiency, safety and stewardship of workplace, community, and environment. To reduce our landfill waste and reduce our environmental impact, we recommend our customers pack their products that ship to Troemner in recyclable packaging including: bubble wrap, plastic air bags, paper, cardboard, or customer cases that can be reused.


To prevent loss and ensure the timely processing and integrity of your precision weights and/or calibration devices, please do not pack in foam peanuts. Please avoid packing your items with foam, packing peanuts or other material, which cannot be recycled.


+ NVLAP Laboratory Code 105013-0

Temperature Calibration Quote Form

Fill out the form below with your Temperature Device and General Contact information to receive a quote within 24 hours.
Required temperature fields must be complete before moving onto General Information

Temperature
5
6
Please list additional requirements or comments. Upload file(s) to assist us with your request. General Information
1
4
Do you require next calibration due date on certificate? Yes No If yes, please list required interval: Type of Device to Calibration Level * Temperature Probe with System Read Out Temperature Probe / Thermometer Only Read Out Only Read Out Manufacturer * Serial Number * Model * Number of Probes * Probe Manufacturer * Serial Number * Model * Read Out Manufacturer * Serial Number * Model *
2
Type of Device * SPRT PRT Thermocouple Thermistor Liquid-in-Glass Read out Temperature Probe with System Read Out
3
Is the device currently in good working condition? Yes No If no, does this device need to be repaired? Yes No Fixed Point Calibration - for reference SPRT's, IPRT's and some Thermistors Comparison Calibration - SPRT's, PRT's, Thermistors, Liquid-in-Glass, Digital Read Outs and Systems Method of Calibration * Comparison Calibration - SPRT's, PRT's, Thermistors, Liquid-in-Glass, Digital Read Outs and Systems Method of Calibration * Comparison Calibration - SPRT's, PRT's, Thermistors, Liquid-in-Glass, Digital Read Outs and Systems Method of Calibration * Comparison Calibration - SPRT's, PRT's, Thermistors, Liquid-in-Glass, Digital Read Outs and Systems Method of Calibration * Digital Read Out Method of Calibration * System Calibration by Comparison Method of Calibration * Level of Service * Level of Service *