Humidity Calibration

Humidity Calibration


At Troemner we address every variable of our measurement process to ensure consistency of calibration, which leads to accurate results in your processes, products and services. Fill out the form below with your Humidity Device and General Contact information to receive a quote within 24 hours.

Calibration Labs Image Gallery

Humidity Calibration Order Forms


An online order form is available at the bottom of the page. Below is a PDF of the Humidity Calibration Order Forms for reference.

Humidity Calibration Order Form

Calibration Certificates

Troemner offers certificates of calibration to meet all of your requirements. Click below to view our sample certificate.
NVLAP Accredited Humidity Certificate of Calibration

Accreditation

ISO/IEC 17025, NVLAP Accredited. NVLAP Laboratory Code 105013-0. Click here for Troemner's NVLAP Accredited Certificate

Laboratory Scope

From 10 % to 95 % Relative Humidity and Dew Point calibration from -20 °C to 70 °C. Click here for Troemner's NVLAP Scope of Accreditation

Service Levels

  • 3 RH points @ 3 Temperatures - Default is 25%, 50%, 75% RH at 19, 21.5, 24 °C as found and as left data.
  • 1 RH point @ 3 Temperatures - Default is 50% RH at 19, 21.5, 24 °C as found and as left data.
  • 3 RH points @ 1 Temperature - Default is 25%, 50%, 75% RH at 21.5 °C as found and as left data.
  • 1 RH @ 1 Temperature - Default is 50% @ 21.5 °C as found and as left data.
  • Additional points available upon request.
  • Humidity Generators - as-found/as-left data for RH, Dew point, Pressure and Flow. Parameters and points dependent upon type and range of generator.

Devices Serviced

Include chart recorders, data loggers, hygrometers, thermohygrometers, hygrothermographs, humidity generators, dew point hygrometers, and humidity chambers. Click for a list of Calibration Devices by Service.

Fast Turnaround Time

2 weeks.

Laboratory Personnel

Metrology staff and technicians are trained by device manufacturers.

Laboratory Processes

Receive device at Troemner’s facility, visually inspect device, contact customer to review service levels requested, collect as-found calibration measurement data, adjust or repair device if required, collect as-left calibration measurement data, calibration certificate is reviewed by an approved signatory, device is packaged and returned to customer.

Need a Repair?

Troemner makes every effort to repair your device. If for any reason you need a repair that cannot be done in house we will facilitate a manufacturer repair on your behalf.

Green Packing Guidelines

Troemner's management systems are dedicated to efficiency, safety and stewardship of workplace, community, and environment. To reduce our landfill waste and reduce our environmental impact, we recommend our customers pack their products that ship to Troemner in recyclable packaging including: bubble wrap, plastic air bags, paper, cardboard, or customer cases that can be reused.


To prevent loss and ensure the timely processing and integrity of your precision weights and/or calibration devices, please do not pack in foam peanuts. Please avoid packing your items with foam, packing peanuts or other material, which cannot be recycled.


+ NVLAP Laboratory Code 10501-0

Humidity Calibration Quote Form

Fill out the form below with your Humidity Device and General Contact information to receive a quote within 24 hours.
Required humidity fields must be complete before moving onto General Information

Humidity
4
5
6
Do you require next calibration due date on certificate? Please list additional requirements or comments regarding this calibration Upload file(s) to assist us with your request. Yes No If yes, please list required interval: General Information
1
Level of Service * RH3RH3T – 3RH points at 3 temperatures – Points are 25%, 50%, 75% RH at 19, 21.5, 24 ºC RH1RH3T – 1 RH point at 3 temperatures – Points are 50% RH at 19, 21.5, 24 ºC RH3RH1T – 3 RH points at 1 temperature – Points are 25%, 50%, 75% RH at 21.5 ºC Do you need custom points *
2
Yes No Type of Device *
3
Integrated System Humidity Probe with System Read Out Humidity Probe Only Manufacturer * Model * Serial Number * Read Out Manufacturer * Model * Serial Number * Manufacturer * Model * Serial Number *
Number of lines for custom points is determined by service *
Manufacturer
Model
Serial Number
 [Remove this]
RH1RH1T – 1RH point at 1 temperature – Points are 505 RH at 21.5 ºC