text.skipToContent text.skipToNavigation

We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it. Learn more at Cookie Policy Site.

Cookie Policy

What is a cookie?

A cookie is a small text file that is stored on your browser when you use websites and applications so that the computer, tablet or mobile device can be recognized at a later time.

Why do we have a cookies policy?

We have implemented a cookies policy as part of our initiative to comply with existing legislation and also to make sure that we are open and clear with you about what happens when you visit this website.

Our cookies policy

TROEMNER, LLC and our partners leverage cookies in several ways, both as first party cookies which are stored from the troemner.com domain, and third party cookies which are stored via our partner domains. We leverage this information in the following ways:

  • As our Site services have a wide global reach, we use cookies to remember your preferred country, language or other settings. This enables us to ensure that the right product offerings are made available to you both during your current and future visits to the Site.
  • We use cookies to authenticate and identify you and/or your registered profile on our Site to provide you with a personalized experience based on your interest and previous visits to the Site.
  • We use cookies to pre-populate your future request forms based on the information you provided in previous request forms.
  • We use cookies to measure the use of our Site in order to improve the Site, tailor the Site and online services according to the interests of our users, and for market research.

If you object to TROEMNER, LLC using these cookies, you can adjust the privacy settings of your browser. Please refer to your specific browser's help function for defining your desired security and privacy settings.

  • eco3.cookiepolicy.show()

0

Products to compare


Compare

Clear

How to Calibrate Balances and Digital Scales: A Step-by-Step Guide.

Key Takeaways:

  • Calibrate Consistently: Calibrate on initial setup, after relocation, and then daily for analytical balances or weekly/monthly for digital scales using either internal auto-calibration or external calibration process.
  • Clean Thoroughly: Clean with a lint-free microfiber cloth and mild solution, remove and dry pans fully, and protect the housing and display from dust and harsh chemicals.
  • Optimal Storage and Use: Store on a flat, vibration-free surface; limit moves; train all users on handling; and leverage Troemner’s stainless-steel, traceable calibration weights and scale weights for reliable performance.

Why You Should Calibrate Your Analytical Balances and Digital Scales

In any lab or industrial setting, accurate measurements are essential—for both scientific integrity and regulatory compliance. Over time, balances and scales may lose accuracy because of:

  • Temperature fluctuations
  • Frequent use
  • Vibrations and movement
  • Dust and environmental factors

Without regular calibration, your weighing device could produce incorrect readings, potentially invalidating results or causing non-compliance. At Troemner, we help you keep your equipment precise with certified calibration weights and scale weights and expert guidance, ensuring consistent and reliable performance.

Step-by-Step: How to Calibrate Balances and Scales

1. Perform Regular Calibration Checks

Whether you're performing an analytical weighing balance calibration or a digital scale verification, calibration helps reset the device to provide accurate readings.

Manual Calibration:

  • Access Calibration Mode: Navigate to the calibration option on your scale’s menu.
  • Use Calibration Weights: Place the appropriate certified weight on the pan.
  • Verify & Adjust: Check the reading and adjust as necessary based on your device’s instructions.

Tip: Calibration procedures may vary and many modern balances offer internal calibration, allowing automatic adjustment with the press of a button—no external weights required.

Note: Analytical balances and precision balances with internal calibration should routinely be checked with external certified weights.

2. How Often Should You Calibrate Your Balance?

Calibration frequency depends on the type of scale, usage intensity, and your working environment. Here’s a general guide:

  • Initial Setup: Always calibrate after first-time installation.
  • After Relocation: Calibrate anytime the balance is moved.
  • High-Precision Use: Calibrate daily for analytical balances.
  • Standard Use: Weekly or monthly for precision and digital scales.

Always follow your lab’s Standard Operating Procedures (SOPs) and industry-specific regulations (e.g., ISO, GLP, GMP).

3. Use High-Quality Calibration Weights and Scale Weights

Troemner offers a full line of ASTM- and OIML-compliant calibration weights made from high-grade stainless steel. These weights:

  • Are certified and traceable to NIST
  • Feature polished finishes for durability and easy cleaning
  • Come with optional calibration certificates for regulated industries

Need help choosing the right weight? Contact Us for personalized support.

How to Clean Your Weighing Balances and Scales for Accurate Results

Routine cleaning reduces dust interference and ensures long-term reliability. Here’s how:

  • Wipe Gently: Use a lint-free microfiber cloth, dampened with a mild, stainless steel-safe cleaning solution.
  • Remove & Clean Pan: Take out the weighing pan, clean it thoroughly, and ensure it's completely dry before reassembly.
  • Screen & Housing: Wipe the display screen and plastic housing using a light detergent.

Avoid: Abrasive cloths, harsh chemicals, or letting fluid seep into internal components.

Proper Use & Storage Tips to Extend Device Life

A well-maintained scale performs more accurately and lasts longer. Follow these storage and usage practices:

  • Train All Users: Ensure proper handling and awareness of weight limits.
  • Place Thoughtfully: Keep the balance on a flat, vibration-free surface, away from airflow and dust.
  • Use a Dust Cover: Protect your device when not in use.
  • Limit Relocation: Move your device as little as possible to avoid recalibration issues.

Frequently Asked Questions (FAQs)

How often should I calibrate a balance and scale?
It depends on the type of scale and how often it's used. Analytical balances often require daily calibration, while standard lab scales can be calibrated weekly or monthly.

Can I calibrate a digital scale myself?
Yes—if your scale supports manual calibration and you have the proper certified weights. Many models also feature internal automatic calibration.

What happens if I skip calibration?
Uncalibrated devices can produce incorrect results, which could compromise experiments, lead to non-compliance, or affect product quality.

Which weights are right for me?
That depends on your device's readability and required standard (ASTM, OIML). Browse Troemner's calibration weights or contact us for guidance.

Conclusion: Accuracy Starts with Proper Calibration

Regular calibration and care of your balances and scales is essential to maintain precision, avoid costly errors, and meet compliance standards. With Troemner’s certified calibration weights and expert support, you're equipped to keep your devices in peak condition.

Ready to calibrate like a pro? Explore Troemner's Calibration Weights

Related Products and Service

Request Custom Quote
This item requires your attention
Currently not available or the item number is not correct
Requires configuration
Item ID
Explanation
Product needs requesting quote first
Some mandatory fields left empty
Contact Us
Availability Request
Warranty Reimbursement
No matching records found
Registration
Products
Show all results
Devices
To find your device, enter the full serial number and run the search
Sorry, there are no results found for your search.
Documents
To find documents, enter the complete serial number, lot number, material / product number or at least 3 characters of the material / product name.
Enter Material/Product Number
Enter Material/Product Name
Enter Serial Number
Enter Lot Number
Enter
Search...
Postal code must be in the format "A#Z ZZZZ"

Are you sure you want to cancel the Quote?

Do you want to delete this item?

  No

It may take up to 24 hours to have your change reflected in all sections of the Installed Devices. Be aware that the changed fields will be blocked from further editing, until the update is performed in the source system. Would you like to proceed?

 
Find documents by
Search Tips
General Product Documentation

Search by material/product number or name for: Manuals, Data Sheets, Application Notes and others.

Device-Specific Documentation

Search by device serial or lot number for: Declarations of Conformity, Production and Materials Certificates and others.